Model |
LDM-110 |
LDM-110EX |
LDM-1000 |
LDM-1000EX |
|
|
|---|---|---|---|---|---|---|
No. of Axes |
For Single |
Max. 2 |
Max. 5 |
Max. 3 |
For Single |
|
Scanning cycle |
400 times/sec |
400 times/sec |
400 times/sec |
400 times/sec |
2000 times/sec |
|
No. of |
1-2048 |
1-2048 |
1-2048(22 steps) at LDM-1000LS |
1-2048 |
||
Measuring mode |
16 kinds |
8 kinds |
16 kinds + Optional edges measurement per each axis |
Optional edges measurement |
||
Processing |
NG |
Average, Difference, Large dia. measurement, etc. |
NG |
|||
Cable cover(Wall) |
NG |
NG |
OK(by LDM-1000XY) |
NG |
||
Display device |
7 segment LED |
Graphic LCD |
7 segment LED |
7 segment LED |
||
No. of Display digit |
4-5 digits |
4-5 digits |
3-6 digits |
3-6 digits |
4-5 digits |
|
Processing |
NG |
NG |
OK |
OK |
NG |
|
Center position |
LED(8pcs) |
LED(8pcs) |
Graphic bargraph |
LED(8pcs) per each axis |
LED(8pcs) |
LED(15pcs) |
No. of channel of |
1 |
1 |
1 channel per board (LDM-1000LS/XY) |
1 |
||
Recorder output |
Max.+/-10V, Resolution 12bits(=approx.10mV/1bit), |
|||||
Recorder output |
1μm-1m/V(decade steps) |
0.1μm~1m/V(decade steps) |
1μm-1m/V(decade steps) |
|||
Digital dia. |
OK |
OK |
NG |
NG |
OK |
NG |
Center value |
5 digits |
5 digits |
6 digits |
6 digits |
5 digits |
|
High/Lo limit |
4 digits |
4 digits |
6 digits |
5 digits |
5 digits |
|
High/Low limit |
1a contact(*2) |
1a contact(*2) per board(LDM-1000LS/XY) |
1a contact(*2) |
|||
Contact rating: AC250V 2A(Resistance load) |
||||||
Error |
1b contact (Close when power OFF) |
1b contact(Close when power OFF) (Combined use by each board) |
1b contact (Close when power OFF) |
|||
Contact rating: AC250V 2A(Resistance load) |
||||||
Laser remote |
OK |
OK |
OK(each LDM-1000LS board) |
OK |
||
Hold terminal |
OK |
OK |
OK(each LDM-1000LS/XY board) |
OK |
||
Edge monitoring |
OK |
OK |
OK |
OK |
OK |
|
Self-diagnosis |
OK |
OK |
OK |
OK |
OK |
|
Multi-point |
OK |
NG |
NG |
NG |
OK |
|
Trigger function |
NG |
NG |
OK |
OK |
NG |
|
Offset |
NG |
NG |
OK |
OK |
NG |
|
Zero set |
OK |
NG |
OK |
OK |
OK |
|
mm/inch |
NG |
NG |
OK |
OK |
NG |
|
Programing |
NG |
NG |
OK(30 kinds) |
OK(9 kinds) |
NG |
|
Graph display |
NG |
NG |
OK |
NG |
NG |
|
Serial port |
OK |
OK |
OK |
OK |
OK |
OK |
BCD output |
Option |
OK(by LDM-1000BCD) |
Option |
|||
Cable length |
Standard 5 meters, Max. 30 meters (Extensible to 120m.max. as option) |
|||||
Power supply |
AC100-240V Free power supply 50/60Hz |
|||||
Power |
less than 11VA |
less than 14VA |
less than 15VA(only display unit) |
less than 15VA |
less than 20VA |
|
Ambient |
Temperature:0-45 degree centigrade, Humidity:35~85%RH(no condensation) |
|||||
Outside |
144(W) * 72(H) * 191(D)[mm] |
216(W) * 144(H) * 225(D)[mm] |
144(W) * 72(H) * 191(D)[mm] |
144(W) * 72(H) * 241(D)[mm] |
||
Weight |
Approx. 1.5kg |
Approx. 1.6kg |
Approx. 4kg (only display unit) |
Approx. 1.5kg |
Approx. 1.8kg |
|
Takikawa also have Cable Extention Adaptor (LDM-201,-202), to be used in case distance between a Laser diameter Scanning Unit and a Display Unit exceeds 30 meters.
Dividing Adaptor (LDM-205,-206), which divides output signals from Scanning Unit.
Laser Diameter LDM-210/LDM-210C uses the detection part of the exclusive use because the scan time is different from the conventional model.
Copyright 2012© T.J. Solution Co.,Ltd.
![]() |
|---|